A comprehensive performance analysis of sequence-based within-sample testing NIPT methods

T.O. Mokveld, Z. Al-Ars, Erik A. Sistermans, M.J.T. Reinders

Research output: Contribution to journalArticleScientificpeer-review

139 Downloads (Pure)

Abstract

Background

Non-Invasive Prenatal Testing is often performed by utilizing read coverage-based profiles obtained from shallow whole genome sequencing to detect fetal copy number variations. Such screening typically operates on a discretized binned representation of the genome, where (ab)normality of bins of a set size is judged relative to a reference panel of healthy samples. In practice such approaches are too costly given that for each tested sample they require the resequencing of the reference panel to avoid technical bias. Within-sample testing methods utilize the observation that bins on one chromosome can be judged relative to the behavior of similarly behaving bins on other chromosomes, allowing the bins of a sample to be compared among themselves, avoiding technical bias.
Results

We present a comprehensive performance analysis of the within-sample testing method Wisecondor and its variants, using both experimental and simulated data. We introduced alterations to Wisecondor to explicitly address and exploit paired-end sequencing data. Wisecondor was found to yield the most stable results across different bin size scales while producing more robust calls by assigning higher Z-scores at all fetal fraction ranges.
Conclusions

Our findings show that the most recent available version of Wisecondor performs best.
Original languageEnglish
Article numbere0284493
Number of pages14
JournalPLoS ONE
Volume18
Issue number4 April
DOIs
Publication statusPublished - 2023

Fingerprint

Dive into the research topics of 'A comprehensive performance analysis of sequence-based within-sample testing NIPT methods'. Together they form a unique fingerprint.

Cite this