A Hidden Markov Model for 3D Catheter Tip Tracking with 2D X-ray Catheterization Sequence and 3D Rotational Angiography

Pierre Ambrosini*, Ihor Smal, Daniel Ruijters, Wiro J. Niessen, Adriaan Moelker, Theo Van Walsum

*Corresponding author for this work

    Research output: Contribution to journalArticleScientificpeer-review

    24 Citations (Scopus)

    Abstract

    In minimal invasive image guided catheterization procedures, physicians require information of the catheter position with respect to the patient's vasculature. However, in fluoroscopic images, visualization of the vasculature requires toxic contrast agent. Static vasculature roadmapping, which can reduce the usage of iodine contrast, is hampered by the breathing motion in abdominal catheterization. In this paper, we propose a method to track the catheter tip inside the patient's 3D vessel tree using intra-operative single-plane 2D X-ray image sequences and a peri-operative 3D rotational angiography (3DRA). The method is based on a hidden Markov model (HMM) where states of the model are the possible positions of the catheter tip inside the 3D vessel tree. The transitions from state to state model the probabilities for the catheter tip to move from one position to another. The HMM is updated following the observation scores, based on the registration between the 2D catheter centerline extracted from the 2D X-ray image, and the 2D projection of 3D vessel tree centerline extracted from the 3DRA. The method is extensively evaluated on simulated and clinical datasets acquired during liver abdominal catheterization. The evaluations show a median 3D tip tracking error of 2.3 mm with optimal settings in simulated data. The registered vessels close to the tip have a median distance error of 4.7 mm with angiographic data and optimal settings. Such accuracy is sufficient to help the physicians with an up-to-date roadmapping. The method tracks in real-time the catheter tip and enables roadmapping during catheterization procedures.

    Original languageEnglish
    Article number7736994
    Pages (from-to)757-768
    Number of pages12
    JournalIEEE Transactions on Medical Imaging
    Volume36
    Issue number3
    DOIs
    Publication statusPublished - 1 Mar 2017

    Keywords

    • 3DRA
    • abdominal
    • breathing
    • catheter
    • catheterization
    • fluoroscopy
    • guidance
    • hidden Markov Model
    • liver
    • registration
    • rigid
    • TACE
    • tip
    • tracking
    • X-ray