N2 - Background and purpose: Scenario-based robust optimization and evaluation are commonly used in proton therapy (PT) with pencil beam scanning (PBS) to ensure adequate dose to the clinical target volume (CTV). However, a statistically accurate assessment of the clinical application of this approach is lacking. In this study, we assess target dose in a clinical cohort of neuro-oncological patients, planned according to the DUPROTON robustness evaluation consensus, using polynomial chaos expansion (PCE). Materials and methods: A cohort of the first 27 neuro-oncological patients treated at HollandPTC was used, including realistic error distributions derived from geometrical and stopping-power prediction (SPP) errors. After validating the model, PCE-based robustness evaluations were performed by simulating 100.000 complete fractionated treatments per patient to obtain accurate statistics on clinically relevant dosimetric parameters and population-dose histograms. Results: Treatment plans that were robust according to clinical protocol and treatment plansin which robustness was sacrificed are easily identified. For robust treatment plans on average, a CTV dose of 3 percentage points (p.p.) more than prescribed was realized (range +2.7 p.p. to +3.5 p.p.) for 98% of the sampled fractionated treatments. For the entire patient cohort on average, a CTV dose of 0.1 p.p. less than prescribed was achieved (range −2.4 p.p. to +0.5 p.p.). For the 6 treatment plans in which robustness was clinically sacrificed, normalized CTV doses of 0.98, 0.94(7)1, 0.94, 0.91, 0.90 and 0.89 were realized. The first of these was clinically borderline non-robust. Conclusion: The clinical robustness evaluation protocol is safe in terms of CTV dose as all plans that fulfilled the clinical robustness criteria were also robust in the PCE evaluation. Moreover, for plans that were non-robust in the PCE-based evaluation, CTV dose was also lower than prescribed in the clinical evaluation.
AB - Background and purpose: Scenario-based robust optimization and evaluation are commonly used in proton therapy (PT) with pencil beam scanning (PBS) to ensure adequate dose to the clinical target volume (CTV). However, a statistically accurate assessment of the clinical application of this approach is lacking. In this study, we assess target dose in a clinical cohort of neuro-oncological patients, planned according to the DUPROTON robustness evaluation consensus, using polynomial chaos expansion (PCE). Materials and methods: A cohort of the first 27 neuro-oncological patients treated at HollandPTC was used, including realistic error distributions derived from geometrical and stopping-power prediction (SPP) errors. After validating the model, PCE-based robustness evaluations were performed by simulating 100.000 complete fractionated treatments per patient to obtain accurate statistics on clinically relevant dosimetric parameters and population-dose histograms. Results: Treatment plans that were robust according to clinical protocol and treatment plansin which robustness was sacrificed are easily identified. For robust treatment plans on average, a CTV dose of 3 percentage points (p.p.) more than prescribed was realized (range +2.7 p.p. to +3.5 p.p.) for 98% of the sampled fractionated treatments. For the entire patient cohort on average, a CTV dose of 0.1 p.p. less than prescribed was achieved (range −2.4 p.p. to +0.5 p.p.). For the 6 treatment plans in which robustness was clinically sacrificed, normalized CTV doses of 0.98, 0.94(7)1, 0.94, 0.91, 0.90 and 0.89 were realized. The first of these was clinically borderline non-robust. Conclusion: The clinical robustness evaluation protocol is safe in terms of CTV dose as all plans that fulfilled the clinical robustness criteria were also robust in the PCE evaluation. Moreover, for plans that were non-robust in the PCE-based evaluation, CTV dose was also lower than prescribed in the clinical evaluation.
KW - DUPROTON robustness protocol
KW - Intensity-modulated proton therapy
KW - Neurological tumors
KW - Polynomial chaos expansion
KW - Robust treatment planning
KW - Setup and range errors
UR - http://www.scopus.com/inward/record.url?scp=85114477274&partnerID=8YFLogxK
U2 - 10.1016/j.radonc.2021.07.028
DO - 10.1016/j.radonc.2021.07.028
M3 - Article
C2 - 34352313
AN - SCOPUS:85114477274
SN - 0167-8140
VL - 163
SP - 121
EP - 127
JO - Radiotherapy and Oncology
JF - Radiotherapy and Oncology
ER -