TY - JOUR
T1 - An Implantable Magnetic Drive Mechanism for Non-Invasive Arteriovenous Conduit Blood Flow Control
AU - White, Nicholas A.
AU - Van Der Kroft, Sander L.
AU - Van Der Bogt, Koen E.A.
AU - Vrielink, Timo J.C.Oude
AU - Camenzuli, Christian
AU - Sanchez-Margallo, Juan A.
AU - Van De Stadt, Huybert J.F.
AU - Dankelman, Jenny
AU - Rotmans, Joris I.
AU - Horeman, Tim
AU - More Authors, null
PY - 2024
Y1 - 2024
N2 - Objective: Hemodialysis patients usually receive an arteriovenous fistula (AVF) in the arm as vascular access conduit to allow dialysis 2-3 times a week. This AVF introduces the high flow necessary for dialysis, but over time the ever-present supraphysiological flow is the leading cause of complications. This study aims to develop an implantable device able to non-invasively remove the high flow outside dialysis sessions. Methods: The developed prototype features a magnetic ring allowing external coupling and torque transmission to non-invasively control an AVF valve. Mock-up devices were implanted into arm and sheep cadavers to test sizes and locations. The transmission torque, output force, and valve closure are measured for different representative skin thicknesses. Results: The prototype was placed successfully into arm and sheep cadavers. In the prototype, a maximum output force of 78.9 ± 4.2 N, 46.7 ± 1.9 N, 25.6 ± 0.7 N, 13.5 ± 0.6 N and 6.3 ± 0.4 N could be achieved non-invasively through skin thicknesses of 1-5 mm respectively. The fistula was fully collapsible in every measurement through skin thickness up to the required 4 mm. Conclusion: The prototype satisfies the design requirements. It is fully implantable and allows closure and control of an AVF through non-invasive torque transmission. In vivo studies are pivotal in assessing functionality and understanding systemic effects. Significance: A method is introduced to transfer large amounts of energy to a medical implant for actuation of a mechanical valve trough a closed surface. This system allows non-invasive control of an AVF to reduce complications related to the permanent high flow in conventional AVFs.
AB - Objective: Hemodialysis patients usually receive an arteriovenous fistula (AVF) in the arm as vascular access conduit to allow dialysis 2-3 times a week. This AVF introduces the high flow necessary for dialysis, but over time the ever-present supraphysiological flow is the leading cause of complications. This study aims to develop an implantable device able to non-invasively remove the high flow outside dialysis sessions. Methods: The developed prototype features a magnetic ring allowing external coupling and torque transmission to non-invasively control an AVF valve. Mock-up devices were implanted into arm and sheep cadavers to test sizes and locations. The transmission torque, output force, and valve closure are measured for different representative skin thicknesses. Results: The prototype was placed successfully into arm and sheep cadavers. In the prototype, a maximum output force of 78.9 ± 4.2 N, 46.7 ± 1.9 N, 25.6 ± 0.7 N, 13.5 ± 0.6 N and 6.3 ± 0.4 N could be achieved non-invasively through skin thicknesses of 1-5 mm respectively. The fistula was fully collapsible in every measurement through skin thickness up to the required 4 mm. Conclusion: The prototype satisfies the design requirements. It is fully implantable and allows closure and control of an AVF through non-invasive torque transmission. In vivo studies are pivotal in assessing functionality and understanding systemic effects. Significance: A method is introduced to transfer large amounts of energy to a medical implant for actuation of a mechanical valve trough a closed surface. This system allows non-invasive control of an AVF to reduce complications related to the permanent high flow in conventional AVFs.
KW - Arteriovenous fistula
KW - Design
KW - Hemodialysis
KW - Implantable device
KW - Transcutaneous energy transmission
UR - http://www.scopus.com/inward/record.url?scp=85199136110&partnerID=8YFLogxK
U2 - 10.1109/TBME.2024.3370263
DO - 10.1109/TBME.2024.3370263
M3 - Article
C2 - 38412078
AN - SCOPUS:85199136110
SN - 0018-9294
VL - 71
SP - 2379
EP - 2390
JO - IEEE Transactions on Biomedical Engineering
JF - IEEE Transactions on Biomedical Engineering
IS - 8
ER -