T1 - Body size measuring techniques enabling stress-free growth monitoring of extreme preterm infants inside incubators
T2 - A systematic review
AU - van Gils, Ronald H.J.
AU - Wauben, Linda S.G.L.
AU - Helder, Onno K.
PY - 2022
Y1 - 2022
N2 - Introduction Growth monitoring of preterm infants is essential for assessing the nutritional effects on their growth. The current growth monitoring techniques are too stressful, however, for the smallest preterm infants. We performed a systematic review to summarize studies on stress-free techniques for measuring the body size of preterm infants inside incubators other than the traditional calliper and tape measure-based instruments. Methods We searched four online literature databases: Embase, Medline, Web of Science Core Collection, and Cochrane, using search terms related to patients (neonates, infants, children) and body size measuring techniques. By means of expert judgement we assessed the techniques’ suitability for stress-free body size measurement of an infant lying in an incubator. As a criterion for suitability, we used an imaginary ideal technique. Results Twenty-six studies were included in this review. In 24 studies, the technique for body size measurement was related to 3D technology, and the majority of these studies acknowledged clinical superiority of 3D over 2D data. Two 3D techniques were assessed as suitable for stress-free measurement of preterm infants inside incubators. The first technique used a commercially available 3D handheld scanner which needed 3D postprocessing to derive measurement data. The second technique used a self-developed stereoscopic vision system. Conclusions 3D volumetric parameters have higher clinical value for growth monitoring than 2D. In addition, contactless 3D measurements enable stress-free growth monitoring of even the smallest preterm infants. However, the time-consuming 3D postprocessing challenges the usability of 3D techniques. Regrettably, none of the identified suitable 3D techniques met all our requirements of an ideal all-in-one body size measuring technique for extreme preterm infants. Handheld 3D scanning might have the best properties for developing this ideal technique.
AB - Introduction Growth monitoring of preterm infants is essential for assessing the nutritional effects on their growth. The current growth monitoring techniques are too stressful, however, for the smallest preterm infants. We performed a systematic review to summarize studies on stress-free techniques for measuring the body size of preterm infants inside incubators other than the traditional calliper and tape measure-based instruments. Methods We searched four online literature databases: Embase, Medline, Web of Science Core Collection, and Cochrane, using search terms related to patients (neonates, infants, children) and body size measuring techniques. By means of expert judgement we assessed the techniques’ suitability for stress-free body size measurement of an infant lying in an incubator. As a criterion for suitability, we used an imaginary ideal technique. Results Twenty-six studies were included in this review. In 24 studies, the technique for body size measurement was related to 3D technology, and the majority of these studies acknowledged clinical superiority of 3D over 2D data. Two 3D techniques were assessed as suitable for stress-free measurement of preterm infants inside incubators. The first technique used a commercially available 3D handheld scanner which needed 3D postprocessing to derive measurement data. The second technique used a self-developed stereoscopic vision system. Conclusions 3D volumetric parameters have higher clinical value for growth monitoring than 2D. In addition, contactless 3D measurements enable stress-free growth monitoring of even the smallest preterm infants. However, the time-consuming 3D postprocessing challenges the usability of 3D techniques. Regrettably, none of the identified suitable 3D techniques met all our requirements of an ideal all-in-one body size measuring technique for extreme preterm infants. Handheld 3D scanning might have the best properties for developing this ideal technique.
UR - http://www.scopus.com/inward/record.url?scp=85128619485&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0267285
DO - 10.1371/journal.pone.0267285
M3 - Review article
C2 - 35452486
AN - SCOPUS:85128619485
VL - 17
JO - PLoS ONE
JF - PLoS ONE
SN - 1932-6203
IS - 4
M1 - e0267285
ER -