Clinically relevant optical properties of bifocal, trifocal, and extended depth of focus intraocular lenses

Damien Gatinel*, Jérôme Loicq

*Corresponding author for this work

Research output: Contribution to journalArticleScientificpeer-review

Abstract

PURPOSE: To experimentally compare the optical performance of three types of hydrophobic intraocular lenses (IOLs): extended depth of focus, bifocal, and trifocal. METHODS: The tested IOLs were: TECNIS ZMB00 (bifocal; Abbott Medical Optics, Abbott Park, IL), TECNIS Symfony ZXR00 (extended depth of focus; Abbott Medical Optics), and FineVision GFree hydrophobic (trifocal; PhysIOL, Liege, Belgium). Their surface topography was analyzed by optical microscopy. Modulation transfer function (MTF) and spherical aberrations were determined on optical bench for variable pupil apertures and with two cornea models (0 fÊm and +0.28 fÊm). United States Air Force target imaging was analyzed for different focal points (near, intermediate, and far). Point spread function (PSF) and halos were quantified and compared. RESULTS: The three lenses presented step-like optic topography. For a pupil size of 3 mm or greater, clearly distinctive MTF peaks were observed for all lenses: two peaks for the extended depth of focus and bifocal lenses with +1.75 and +4.00 diopters (D) addition, respectively, and three peaks for the trifocal lens with +1.75 and +3.50 addition for intermediate and near vision, respectively. The extended depth of focus and bifocal lens had slightly higher MTF at best focus with the +0.28 fÊm cornea model than with the 0 fÊm model, whereas the trifocal lens was likely to be more independent of the corneal spherical aberrations. CONCLUSIONS: It appears that the three lenses rely on light diffraction for their optical performance, presenting halos with comparable intensities. For small pupil apertures (< 3 mm), the MTF peaks for the far and intermediate focal distances of the trifocal and extended depth of focus lenses overlap, but the trifocal lens presented an additional MTF peak for the near focal points.

Original languageEnglish
Pages (from-to)273-280
Number of pages8
JournalJournal of Refractive Surgery
Volume32
Issue number4
DOIs
Publication statusPublished - Apr 2016

Bibliographical note

Publisher Copyright:
Copyright © SLACK Incorporated.

Fingerprint

Dive into the research topics of 'Clinically relevant optical properties of bifocal, trifocal, and extended depth of focus intraocular lenses'. Together they form a unique fingerprint.

Cite this