TY - JOUR
T1 - Determination of 54 elements in lichen transplants
T2 - Comparison of INAA, ICPMS, and EDXRF
AU - Pantelica, Ana
AU - Cercasov, Vadim
AU - Steinnes, Eiliv
AU - Bode, Peter
AU - Wolterbeek, Hubert Th
PY - 2016
Y1 - 2016
N2 - Three multi-element techniques employed for analysis of lichen transplants deployed at sites in Romania with strongly differing exposure to air pollutants were compared with respect to precision and determination limits for 54 elements. The results obtained for Evernia prunastri (unexposed and 6 months’ exposure at three sites) are presented here. The techniques were energy dispersive X-ray fluorescence analysis (EDXRF), sector-field inductively-coupled plasma mass spectrometry (ICPMS), and instrumental neutron activation analysis (INAA). From an assessment of the data the EDXRF values were preferred for 3 elements (Ni, Cu, Pb), ICPMS for 18 elements (B, Mg, P, Ga, Rb, Sr, Y, Mo, Ag, Cd, In, Sn, Cs, Ba, Pr, Hg, Tl, Bi), and INAA for 23 elements (Na, Al, Cl, Ti, Cr, Co, Se, Br, I, La, Ce, Sm, Eu, Tb, Dy, Yb, Lu, Hf, Ta, W, Au, Th, U). For the remaining 10 elements (S, K, Ca, Sc, V, Mn, Fe, Zn, As, Sb) two or all three techniques gave results of similar quality. In spite of good performance relative to certified reference materials the ICPMS data for some elements were systematic low relative to corresponding data from INAA and EDXRF, presumably because the samples contained mineral matter not dissolved in the nitric acid dissolution for ICPMS.
AB - Three multi-element techniques employed for analysis of lichen transplants deployed at sites in Romania with strongly differing exposure to air pollutants were compared with respect to precision and determination limits for 54 elements. The results obtained for Evernia prunastri (unexposed and 6 months’ exposure at three sites) are presented here. The techniques were energy dispersive X-ray fluorescence analysis (EDXRF), sector-field inductively-coupled plasma mass spectrometry (ICPMS), and instrumental neutron activation analysis (INAA). From an assessment of the data the EDXRF values were preferred for 3 elements (Ni, Cu, Pb), ICPMS for 18 elements (B, Mg, P, Ga, Rb, Sr, Y, Mo, Ag, Cd, In, Sn, Cs, Ba, Pr, Hg, Tl, Bi), and INAA for 23 elements (Na, Al, Cl, Ti, Cr, Co, Se, Br, I, La, Ce, Sm, Eu, Tb, Dy, Yb, Lu, Hf, Ta, W, Au, Th, U). For the remaining 10 elements (S, K, Ca, Sc, V, Mn, Fe, Zn, As, Sb) two or all three techniques gave results of similar quality. In spite of good performance relative to certified reference materials the ICPMS data for some elements were systematic low relative to corresponding data from INAA and EDXRF, presumably because the samples contained mineral matter not dissolved in the nitric acid dissolution for ICPMS.
KW - Air pollution
KW - EDXRF
KW - ICPMS
KW - INAA
KW - Lichen transplant
KW - Multi-element study
UR - http://www.scopus.com/inward/record.url?scp=84990963865&partnerID=8YFLogxK
M3 - Article
AN - SCOPUS:84990963865
VL - 61
SP - 1380
EP - 1388
JO - Romanian Journal of Physics
JF - Romanian Journal of Physics
SN - 1221-146X
IS - 7-8
ER -