T1 - Dual Mode Electronic Quality Factor Control of 2D Phased Array Ultrasound Transducers for Imaging and Neuromodulation
AU - Radhakrishnan, Anand A.
AU - Aqamolaei, Masoumeh
AU - Costa, Tiago L.
N1 - Green Open Access added to TU Delft Institutional Repository as part of the Taverne amendment. More information about this copyright law amendment can be found at https://www.openaccess.nl. Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.
PY - 2025
Y1 - 2025
N2 - Ultrasound (US) technology has emerged as a powerful modality in both medical imaging and therapy, offering non-invasive, real-time, and high-resolution capabilities. Conventional dual-mode systems employ separate US transducers for imaging and therapy, each mechanically configured during fabrication for a fixed quality factor (Q-factor) through the presence of a backing layer or air-based backing layer, respectively. This approach increases system cost, physical footprint, power consumption, and integration complexity while preventing seamless real-time switching between modes. A novel electronically configurable Q-factor control circuit architecture for a single set of 2D phased-array piezoelectric transducers is proposed in this work. The proposed method employs an active damping compensation technique to electronically reduce the Q-factor during imaging mode while preserving the high-Q state for the therapeutic mode, eliminating the need for mechanical reconfiguration. System and circuit-level simulations in TSMC 180 nm BCD technology using a PZT-5A air-backed transducer BVD model demonstrate a reduction in the Q-factor from 78.3 to 8.08 with fewer than 1% variation across PVT corners. These results place the Q-factor achieved in the imaging mode within the optimal range for high-resolution ultrasound imaging, while maintaining high-Q performance for the therapeutic mode.
AB - Ultrasound (US) technology has emerged as a powerful modality in both medical imaging and therapy, offering non-invasive, real-time, and high-resolution capabilities. Conventional dual-mode systems employ separate US transducers for imaging and therapy, each mechanically configured during fabrication for a fixed quality factor (Q-factor) through the presence of a backing layer or air-based backing layer, respectively. This approach increases system cost, physical footprint, power consumption, and integration complexity while preventing seamless real-time switching between modes. A novel electronically configurable Q-factor control circuit architecture for a single set of 2D phased-array piezoelectric transducers is proposed in this work. The proposed method employs an active damping compensation technique to electronically reduce the Q-factor during imaging mode while preserving the high-Q state for the therapeutic mode, eliminating the need for mechanical reconfiguration. System and circuit-level simulations in TSMC 180 nm BCD technology using a PZT-5A air-backed transducer BVD model demonstrate a reduction in the Q-factor from 78.3 to 8.08 with fewer than 1% variation across PVT corners. These results place the Q-factor achieved in the imaging mode within the optimal range for high-resolution ultrasound imaging, while maintaining high-Q performance for the therapeutic mode.
KW - Active Damping system
KW - Phased arrays
KW - Quality Factor
KW - Ultrasound Imaging
KW - Ultrasound neuromodulation
UR - https://www.scopus.com/pages/publications/105021827727
U2 - 10.1109/IUS62464.2025.11201673
DO - 10.1109/IUS62464.2025.11201673
M3 - Conference contribution
AN - SCOPUS:105021827727
T3 - IEEE International Ultrasonics Symposium, IUS
BT - 2025 IEEE International Ultrasonics Symposium, IUS 2025
PB - IEEE
T2 - 2025 IEEE International Ultrasonics Symposium, IUS 2025
Y2 - 15 September 2025 through 18 September 2025
ER -