TY - JOUR
T1 - Dynamic Light Scattering
T2 - A New Noninvasive Technology for Neonatal Heart Rate Monitoring
AU - Gangaram-Panday, Norani H.
AU - van Essen, Tanja
AU - Goos, Tom
AU - De Jonge, Rogier C.J.
AU - Reiss, Irwin K.M.
AU - van Weteringen, Willem
PY - 2020
Y1 - 2020
N2 - Heart rate (HR) detection in premature infants using electrocardiography (ECG) is challenging due to a low signal amplitude and the fragility of the premature skin. Recently, the dynamic light scattering (DLS) technique has been miniaturized, allowing noninvasive HR measurements with a single sensor. Objective: The aim was to determine the accuracy of DLS for HR measurement in infants, compared to ECG-derived HR. Methods: Stable infants with a gestational age of ≥26 weeks, monitored with ECG, were eligible for inclusion. HR was measured with the DLS sensor at 5 different sites for 15 min each. We recorded every 10th second of the DLS-derived HR and the DLS signal-to-noise ratio (SNR), and the ECG-derived HR was extracted for analysis. Patients were randomly divided into 2 groups. In the first group, the optimal SNR cut-off value was determined and then applied to the second group to assess agreement. Results: HR measurements from 31 infants were analyzed. ECG-DLS paired data points were collected at the forehead, an upper extremity, the thorax, a lower extremity, and the abdomen. When applying the international accuracy standard for HR detection, DLS accuracy in the first group (n = 15) was optimal at the forehead (SNR cut-off 1.66). Application of this cut-off to the second group (n = 16) showed good agreement between DLS-derived HR and ECG-derived HR (bias –0.73 bpm; 95% limits of agreement –15.46 and 14.00 bpm) at the forehead with approximately 80% (i.e., 1,066/1,310) of all data pairs remaining. Conclusion: The investigated DLS sensor was sensitive to movement, overall providing less accurate HR measurements than ECG and pulse oximetry. In this study population, specific measurement sites provided excellent signal quality and good agreement with ECG-derived HR.
AB - Heart rate (HR) detection in premature infants using electrocardiography (ECG) is challenging due to a low signal amplitude and the fragility of the premature skin. Recently, the dynamic light scattering (DLS) technique has been miniaturized, allowing noninvasive HR measurements with a single sensor. Objective: The aim was to determine the accuracy of DLS for HR measurement in infants, compared to ECG-derived HR. Methods: Stable infants with a gestational age of ≥26 weeks, monitored with ECG, were eligible for inclusion. HR was measured with the DLS sensor at 5 different sites for 15 min each. We recorded every 10th second of the DLS-derived HR and the DLS signal-to-noise ratio (SNR), and the ECG-derived HR was extracted for analysis. Patients were randomly divided into 2 groups. In the first group, the optimal SNR cut-off value was determined and then applied to the second group to assess agreement. Results: HR measurements from 31 infants were analyzed. ECG-DLS paired data points were collected at the forehead, an upper extremity, the thorax, a lower extremity, and the abdomen. When applying the international accuracy standard for HR detection, DLS accuracy in the first group (n = 15) was optimal at the forehead (SNR cut-off 1.66). Application of this cut-off to the second group (n = 16) showed good agreement between DLS-derived HR and ECG-derived HR (bias –0.73 bpm; 95% limits of agreement –15.46 and 14.00 bpm) at the forehead with approximately 80% (i.e., 1,066/1,310) of all data pairs remaining. Conclusion: The investigated DLS sensor was sensitive to movement, overall providing less accurate HR measurements than ECG and pulse oximetry. In this study population, specific measurement sites provided excellent signal quality and good agreement with ECG-derived HR.
KW - Noninvasive measurement
KW - Dynamic light scattering
KW - Neonate
KW - Heart rate
KW - Sensor
UR - http://www.scopus.com/inward/record.url?scp=85086463270&partnerID=8YFLogxK
U2 - 10.1159/000506771
DO - 10.1159/000506771
M3 - Article
SN - 1661-7819
VL - 117
SP - 279
EP - 286
JO - Neonatology
JF - Neonatology
IS - 3
ER -