N2 - Real-time proton therapy range verification is a technique that can potentially reduce uncertainty margins around the treatment volume and enable prompt corrections during treatment, making proton therapy a safer cancer treatment modality. Imaging secondary particles resulting from proton-beam nuclear interactions with tissue serves as a means of range verification. The NOVO project recently (2023) presented a compact detector array (NOVCoDA) range verification system designed to image secondary prompt-gamma rays (PGs) and fast neutrons (FNs). The position resolution and arrangement of detector elements within the NOVCoDA influences the reconstructed particle distributions and in turn the system's range shift detection capabilities. Through Monte-Carlo simulations, we investigate the effects of four different detector element arrangements and the utilization of optically segmented scintillator volumes within detector elements, for improved position resolution, on NOVCoDA's range shift determination capability for proton therapy. We limit our study to the detection of FNs produced by an 85-MeV proton beam interacting within a homogeneous water phantom. Results indicate that a parallel array with detector elements oriented perpendicular to the proton beam axis and line-of-sight direction yields the highest double FN scattering efficiency, on order of 10−6 per proton. Furthermore, optically segmented detector elements resulted in improved minimum detectable range shift, reducing required proton intensity by 30%–60% to discern a 1 mm shift.
AB - Real-time proton therapy range verification is a technique that can potentially reduce uncertainty margins around the treatment volume and enable prompt corrections during treatment, making proton therapy a safer cancer treatment modality. Imaging secondary particles resulting from proton-beam nuclear interactions with tissue serves as a means of range verification. The NOVO project recently (2023) presented a compact detector array (NOVCoDA) range verification system designed to image secondary prompt-gamma rays (PGs) and fast neutrons (FNs). The position resolution and arrangement of detector elements within the NOVCoDA influences the reconstructed particle distributions and in turn the system's range shift detection capabilities. Through Monte-Carlo simulations, we investigate the effects of four different detector element arrangements and the utilization of optically segmented scintillator volumes within detector elements, for improved position resolution, on NOVCoDA's range shift determination capability for proton therapy. We limit our study to the detection of FNs produced by an 85-MeV proton beam interacting within a homogeneous water phantom. Results indicate that a parallel array with detector elements oriented perpendicular to the proton beam axis and line-of-sight direction yields the highest double FN scattering efficiency, on order of 10−6 per proton. Furthermore, optically segmented detector elements resulted in improved minimum detectable range shift, reducing required proton intensity by 30%–60% to discern a 1 mm shift.
KW - Fast neutron imaging
KW - Monte Carlo simulation
KW - Organic scintillators
KW - Proton therapy range verification
UR - http://www.scopus.com/inward/record.url?scp=105002493382&partnerID=8YFLogxK
U2 - 10.1016/j.radphyschem.2025.112793
DO - 10.1016/j.radphyschem.2025.112793
M3 - Article
AN - SCOPUS:105002493382
SN - 0969-806X
VL - 234
JO - Radiation Physics and Chemistry
JF - Radiation Physics and Chemistry
M1 - 112793