Face, content, and construct validity of the take-home eosim augmented reality laparoscopy simulator for basic laparoscopic tasks

Elke E.A. Arts*, Erik Leijte, Bart P.L. Witteman, Jack J. Jakimowicz, Bas Verhoeven, Sanne M.B.I. Botden

*Corresponding author for this work

Research output: Contribution to journalArticleScientificpeer-review

14 Citations (Scopus)

Abstract

Background: The eoSim® laparoscopic augmented reality (AR) simulator has instrument tracking capabilities that may be suitable for implementation in laparoscopic training. The objective is to assess face, content, and construct validity of this simulator for basic laparoscopic skills training. Methods: Participants were divided into three groups: novices (no training), intermediates (<50 laparoscopic procedures), and experts (>50 laparoscopic procedures). Three basic tasks were completed on the simulator: thread transfer (1), cyst dissection (2), and tube ligation (3). A questionnaire was completed on realism, didactic value, and usability of the simulator. Measured outcome parameters were as follows: time, distance, time off screen, average speed, acceleration, and smoothness. Results: Mean ± standard deviation scores on realism were positive (Task 1 or T1; 3.9 ± 0.7, P = .13, T2; 3.7 ± 0.7, P = .07, T3; 3.7 ± 0.07), as well as didactic value (T1; 3.9 ± 0.8, P = .71, T2; 3.9 ± 0.8, P = .31, T3; 4.0 ± 0.8, P = .40). Usability was valued the highest, with mean scores between 3.9 and 4.3 (T1; P = .71, T2; P = .80, T3; P = .85). Scores did not differ significantly between groups. Experts were significantly faster (Task 1; P < .001, Task 2; P = .042, Task 3: P < .001) with higher handling speed for tasks 2 and 3 (Task 1; P = .20, task 2; P = .034, task 3; P = .049). Results for other outcome parameters also indicated experts had better instrument control and efficiency than novices, although these differences did not reach statistical significance. Conclusions: The eoSim laparoscopic AR simulator is regarded as a realistic, accessible, and useful tool for the training of basic laparoscopic skills, with good face validity. Construct validity of the eoSim AR simulator was demonstrated on several core variables, but not all.

Original languageEnglish
Pages (from-to)1419-1426
Number of pages8
JournalJournal of Laparoendoscopic and Advanced Surgical Techniques
Volume29
Issue number11
DOIs
Publication statusPublished - 2019

Keywords

  • laparoscopy training
  • simulation
  • validity

Fingerprint

Dive into the research topics of 'Face, content, and construct validity of the take-home eosim augmented reality laparoscopy simulator for basic laparoscopic tasks'. Together they form a unique fingerprint.

Cite this