TY - JOUR
T1 - Fault diagnosis of the 10MW Floating Offshore Wind Turbine benchmark
T2 - A mixed model and signal-based approach
AU - Liu, Yichao
AU - Ferrari, Riccardo M.G.
AU - Wu, Ping
AU - Jiang, Xiaoli
AU - Li, Sunwei
AU - van Wingerden, Jan-Willem
PY - 2021
Y1 - 2021
N2 - Floating Offshore Wind Turbines (FOWTs) operate in the harsh marine environment with limited accessibility and maintainability. Not only failures are more likely to occur than in land-based turbines, but also corrective maintenance is more expensive. In the present study, a mixed model and signal-based Fault Diagnosis (FD) architecture is developed to detect and isolate critical faults in FOWTs. More specifically, a model-based scheme is developed to detect and isolate the faults associated with the turbine system. It is based on a fault detection and approximation estimator and fault isolation estimators, with time-varying adaptive thresholds to guarantee against false-alarms. In addition, a signal-based scheme is established, within the proposed architecture, for detecting and isolating two representative mooring lines faults. For the purpose of verification, a 10MW FOWT benchmark is developed and its operating conditions, which contains predefined faults, are simulated by extending the high-fidelity simulator. Based on it, the effectiveness of the proposed architecture is illustrated. In addition, the advantages and limitations are discussed by comparing its fault detection to the results delivered by other approaches. Results show that the proposed architecture has the best performance in detecting and isolating the critical faults in FOWTs under diverse operating conditions.
AB - Floating Offshore Wind Turbines (FOWTs) operate in the harsh marine environment with limited accessibility and maintainability. Not only failures are more likely to occur than in land-based turbines, but also corrective maintenance is more expensive. In the present study, a mixed model and signal-based Fault Diagnosis (FD) architecture is developed to detect and isolate critical faults in FOWTs. More specifically, a model-based scheme is developed to detect and isolate the faults associated with the turbine system. It is based on a fault detection and approximation estimator and fault isolation estimators, with time-varying adaptive thresholds to guarantee against false-alarms. In addition, a signal-based scheme is established, within the proposed architecture, for detecting and isolating two representative mooring lines faults. For the purpose of verification, a 10MW FOWT benchmark is developed and its operating conditions, which contains predefined faults, are simulated by extending the high-fidelity simulator. Based on it, the effectiveness of the proposed architecture is illustrated. In addition, the advantages and limitations are discussed by comparing its fault detection to the results delivered by other approaches. Results show that the proposed architecture has the best performance in detecting and isolating the critical faults in FOWTs under diverse operating conditions.
KW - Fault diagnosis
KW - floating offshore wind turbine
KW - model-based scheme
KW - Signal-based scheme
KW - FAST simulation
UR - http://www.scopus.com/inward/record.url?scp=85091644126&partnerID=8YFLogxK
U2 - 10.1016/j.renene.2020.06.130
DO - 10.1016/j.renene.2020.06.130
M3 - Article
VL - 164
SP - 391
EP - 406
JO - Renewable Energy
JF - Renewable Energy
SN - 0960-1481
ER -