Femur auxetic meta-implants with tuned micromotion distribution

Naeim Ghavidelnia, Mahdi Bodaghi, Reza Hedayati

Research output: Contribution to journalArticleScientificpeer-review

4 Citations (Scopus)
11 Downloads (Pure)

Abstract

Stress shielding and micromotions are the most significant problems occurring at the bone-implants interface due to a mismatch of their mechanical properties. Mechanical 3D metamate-rials, with their exceptional behaviour and characteristics, can provide an opportunity to solve the mismatch of mechanical properties between the bone and implant. In this study, a new porous femoral hip meta-implant with graded Poisson’s ratio distribution was introduced and its results were compared to three other femoral hip implants (one solid implant, and two porous meta-implants, one with positive and the other with a negative distribution of Poisson’s ratio) in terms of stress and micromotion distributions. For this aim, first, a well-known auxetic 3D re-entrant structure was studied analytically, and precise closed-form analytical relationships for its elastic modulus and Poisson’s ratio were derived. The results of the analytical solution for mechanical properties of the 3D re-entrant structure presented great improvements in comparison to previous analytical studies on the structure. Moreover, the implementation of the re-entrant structure in the hip implant provided very smooth results for stress and strain distributions in the lattice meta-implants and could solve the stress shielding problem which occurred in the solid implant. The lattice meta-implant based on the graded unit cell distribution presented smoother stress-strain distribution in comparison with the other lattice meta-implants. Moreover, the graded lattice meta-implant gave minimum areas of local stress and local strain concentration at the contact region of the implants with the internal bone surfaces. Among all the cases, the graded meta-implant also gave micromotion levels which are the closest to values reported to be desirable for bone growth (40 µm).

Original languageEnglish
Article number114
Pages (from-to)1-30
Number of pages30
JournalMaterials
Volume14
Issue number1
DOIs
Publication statusPublished - 2021

Keywords

  • 3D auxetic
  • Hip implant
  • Mechanical metamaterial
  • Porous biomaterials

Fingerprint

Dive into the research topics of 'Femur auxetic meta-implants with tuned micromotion distribution'. Together they form a unique fingerprint.

Cite this