Fragility curves for unanchored medical equipment accounting for building and content interaction

Jaime Guamán-Cabrera*, Juan Carlos de la Llera, Tiziana Rossetto, Luis Enberg, Ioanna Ioannou

*Corresponding author for this work

Research output: Contribution to journalArticleScientificpeer-review

Abstract

Currently, construction codes and standards require nonstructural fragility information to define nonstructural performance objectives and expectations for low- and design-intensity earthquake motions. To address this knowledge gap, this study focuses on the development of analytical fragility curves for unanchored medical equipment commonly found in hospital critical rooms, taking into account the building’s performance, damage progression, and content interaction simultaneously. To achieve this goal, a fully equipped emergency room, intensive care unit, and operating room are simulated on the first, fourth, and fifth floors of a mid-rise hospital building, respectively, and subjected to service, design, and maximum considered earthquake levels under fixed-to-the-base (FB) and base-isolated (BI) support conditions. The building’s floor acceleration responses are used as input motions to assess the performance of several pieces of medical equipment using rolling and sliding nonlinear models. This study has included a comprehensive uncertainty analysis to propagate different sources of uncertainty into the fragility curves. Fragility results indicate that, under FB support conditions, equipment malfunctions and failures are expected to occur during low-intensity earthquake motions, even if the hospital building experiences minor structural damage. Furthermore, knowing the damaged condition of medical equipment (malfunction/failure) is crucial for determining its availability and subsequent use to stabilize critical condition patients or save their lives. Finally, these fragility curves can be used to plan post-disaster recovery and make risk-informed decisions in healthcare facilities.

Original languageEnglish
Article number121494
Number of pages23
JournalEngineering Structures
Volume346
DOIs
Publication statusPublished - 2025

Bibliographical note

Green Open Access added to TU Delft Institutional Repository as part of the Taverne amendment. More information about this copyright law amendment can be found at https://www.openaccess.nl.

Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.

Keywords

  • Base isolation
  • Fragility
  • Hospital
  • Interaction
  • Medical equipment
  • Performance-based
  • Uncertainty

Fingerprint

Dive into the research topics of 'Fragility curves for unanchored medical equipment accounting for building and content interaction'. Together they form a unique fingerprint.

Cite this