TY - JOUR
T1 - Instantaneous mesh load factor ( K3) measurements in a wind turbine gearbox using fiber-optic strain sensors
AU - Gutierrez-Santiago, Unai
AU - Keller, Jonathan
AU - Fernández-Sisón, Alfredo
AU - Polinder, Henk
AU - Van Wingerden, Jan Willem
PY - 2024
Y1 - 2024
N2 - The mesh load factor, K 3, describes how loads are shared between planet gears and has become one of the key design challenges in modern wind turbine gearboxes. Planet load sharing directly impacts tooth root stresses, a critical driver of torque density and gearbox reliability. Experimental evaluation of K 3 is typically performed from sun gear tooth root strain gauge measurements, which are complex. Furthermore, such measurements can only provide an average value of load sharing. The present study describes an alternative method to evaluate the mesh load factor in wind turbine gearboxes based on fiber-optic strain sensors installed on the outer surface of the fixed ring gear. We present the results of an extensive measurement campaign to evaluate this novel sensing solution installed on the input planetary stage of a 2-MW wind turbine gearbox at the National Renewable Energy Laboratory's Flatirons Campus (Colorado, USA). The number of strain sensors on the ring gear was selected as an integer multiple of the number of planets, which has enabled an instantaneous evaluation of the mesh load factor. The effect of operating conditions on the planet load-sharing behavior of the gearbox has been investigated. The mesh load factor measured for operating conditions close to rated was below 1.05, well below IEC 61400-4 standard requirements.
AB - The mesh load factor, K 3, describes how loads are shared between planet gears and has become one of the key design challenges in modern wind turbine gearboxes. Planet load sharing directly impacts tooth root stresses, a critical driver of torque density and gearbox reliability. Experimental evaluation of K 3 is typically performed from sun gear tooth root strain gauge measurements, which are complex. Furthermore, such measurements can only provide an average value of load sharing. The present study describes an alternative method to evaluate the mesh load factor in wind turbine gearboxes based on fiber-optic strain sensors installed on the outer surface of the fixed ring gear. We present the results of an extensive measurement campaign to evaluate this novel sensing solution installed on the input planetary stage of a 2-MW wind turbine gearbox at the National Renewable Energy Laboratory's Flatirons Campus (Colorado, USA). The number of strain sensors on the ring gear was selected as an integer multiple of the number of planets, which has enabled an instantaneous evaluation of the mesh load factor. The effect of operating conditions on the planet load-sharing behavior of the gearbox has been investigated. The mesh load factor measured for operating conditions close to rated was below 1.05, well below IEC 61400-4 standard requirements.
UR - http://www.scopus.com/inward/record.url?scp=85197275322&partnerID=8YFLogxK
U2 - 10.1088/1742-6596/2767/4/042022
DO - 10.1088/1742-6596/2767/4/042022
M3 - Conference article
AN - SCOPUS:85197275322
SN - 1742-6588
VL - 2767
JO - Journal of Physics: Conference Series
JF - Journal of Physics: Conference Series
IS - 4
M1 - 042022
T2 - 2024 Science of Making Torque from Wind, TORQUE 2024
Y2 - 29 May 2024 through 31 May 2024
ER -