Mechanically fastened shear connectors in prefabricated concrete slabs-experimental analysis

Nina Gluhović*, Zlatko Marković, Milan Spremić, Marko Pavlović

*Corresponding author for this work

Research output: Contribution to journalArticleScientificpeer-review

3 Citations (Scopus)

Abstract

Nowadays, in prefabricated composite construction, composite action between steel beam and concrete slab is often achieved with positioning of shear connectors in envisaged openings of concrete slabs. Prefabricated concrete slabs are used for composite steel-concrete buildings and bridges, both for the construction of new structures and for renovation of existing ones, significantly reducing construction time. Development of different types of shear connectors represent alternative solution to the traditionally used headed studs, considering their shear resistance, stiffness and ductility. New types of shear connectors tend to reduce the construction time and overall construction cost. Mechanically fastened shear connectors represent a viable alternative to headed studs, considering their fast installation process and shear resistance. X-HVB shear connectors are attached to the steel beam with two cartridge fired pins. The first step towards extensive implementation of X-HVB shear connectors in composite construction is to understand their behaviour through experimental investigation. Results of the push-out tests, in accordance to Eurocode 4, with X-HVB 110 shear connectors positioned in envisaged openings of prefabricated concrete slabs are presented in this paper. The experimental investigation comprised three different specimen's layout. Group arrangement of X-HVB shear connectors in envisaged openings included specimens with minimal recommended distances and specimens with reduced distances between connectors in both directions. Influence of different installation procedures on overall behaviour of the connection is presented, as well as the orientation of shear connectors relative to the shear force direction. Influence of variations is characterized in terms of failure mechanisms, shear resistance and ductility.

Original languageEnglish
Pages (from-to)369-381
Number of pages13
JournalSteel and Composite Structures
Volume36
Issue number4
DOIs
Publication statusPublished - 2020

Keywords

  • Cartridge fired pins
  • Push-out test
  • Steel-concrete composite structures
  • X-HVB, experiments

Fingerprint

Dive into the research topics of 'Mechanically fastened shear connectors in prefabricated concrete slabs-experimental analysis'. Together they form a unique fingerprint.

Cite this