The DC transmission line protection technology is crucial for the development of multi-terminal Voltage Source Converter (VSC)-based HVDC systems. This article proposes a robust non-unit traveling wave protection (TWP), which deals with the DC fault area identification and fault type discrimination for high impedance fault conditions. The authors applied the traveling wave (TW) reflection and refraction method for the line-mode network. The distinctive features of high-frequency components contained in the line-mode and pole-mode voltage TWs at different relay units are used for the algorithm modeling. Discrete Wavelet Transform (DWT) is selected as the time-frequency analysis tool. The performed simulations are conducted for a four-terminal VSC-HVDC system, and validate the protection feasibility and robustness. More precisely, the proposed protection scheme identifies the internal and external DC faults within 2 ms, and provides correct operation during high-impedance faults (HIF) with a 25 dB level noise interference. This protection scheme makes use of a VSC-assisted resonant current (VARC) direct current circuit breaker (DCCB), that successfully interrupts the fault currents in less than 10 ms after the fault inception. The authors also comprehensively compared the proposed scheme with the existing methods. The obtained results show that the proposed protection scheme is superior in terms of sensitivity and selectivity performance.

Original languageEnglish
Pages (from-to)3117-3129
Number of pages13
JournalIEEE Transactions on Power Delivery
Volume38
Issue number5
DOIs
Publication statusPublished - 2023

Bibliographical note

Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-care
Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.

Keywords

  • Non-unit protection
  • modular multi-level converter (MMC)
  • high voltage direct current (HVDC)
  • DC circuit breakers (DCCB)
  • discrete wavelet transform (DWT)

Fingerprint