Semi-automated digital workflow to design and evaluate patient-specific mandibular reconstruction implants

A. van Kootwijk, V. Moosabeiki, M. Cruz Saldivar, H. Pahlavani, M. A. Leeflang, S. Kazemivand Niar, N. Tümer, M. Mirzaali Mazandarani, J. Zhou, A. A. Zadpoor, More Authors

Research output: Contribution to journalArticleScientificpeer-review

7 Citations (Scopus)
127 Downloads (Pure)

Abstract

The reconstruction of large mandibular defects with optimal aesthetic and functional outcomes remains a major challenge for maxillofacial surgeons. The aim of this study was to design patient-specific mandibular reconstruction implants through a semi-automated digital workflow and to assess the effects of topology optimization on the biomechanical performance of the designed implants. By using the proposed workflow, a fully porous implant (LA-implant) and a topology-optimized implant (TO-implant) both made of Ti-6Al-4V ELI were designed and additively manufactured using selective laser melting. The mechanical performance of the implants was predicted by performing finite element analysis (FEA) and was experimentally assessed by conducting quasi-static and cyclic biomechanical tests. Digital image correlation (DIC) was used to validate the FE model by comparing the principal strains predicted by the FEM model with the measured distribution of the same type of strain. The numerical predictions were in good agreement with the DIC measurements and the predicted locations of specimen failure matched the actual ones. No statistically significant differences (p < 0.05) in the mean stiffness, mean ultimate load, or mean ultimate displacement were detected between the LA- and TO-implant groups. No implant failures were observed during quasi-static or cyclic testing under masticatory loads that were substantially higher (>1000 N) than the average maximum biting force of healthy individuals. Given its relatively lower weight (16.5%), higher porosity (17.4%), and much shorter design time (633.3%), the LA-implant is preferred for clinical application. This study clearly demonstrates the capability of the proposed workflow to develop patient-specific implants with high precision and superior mechanical performance, which will greatly facilitate cost- and time-effective pre-surgical planning and is expected to improve the surgical outcome.

Original languageEnglish
Article number105291
Number of pages14
JournalJournal of the mechanical behavior of biomedical materials
Volume132
DOIs
Publication statusPublished - 2022

Keywords

  • Biomechanical validation
  • Finite element analysis
  • Implant design workflow
  • Mandibular reconstruction
  • Patient-specific implant
  • Topology optimization

Fingerprint

Dive into the research topics of 'Semi-automated digital workflow to design and evaluate patient-specific mandibular reconstruction implants'. Together they form a unique fingerprint.

Cite this