Abstract
Background During Transcranial Magnetic Stimulation (TMS) experiments researchers often use a neuronavigation system to precisely and accurately maintain coil position and orientation. New method This study aimed to develop and validate an open-source software for TMS coil navigation. StimTrack uses an optical tracker and an intuitive user interface to facilitate the maintenance of position and orientation of any type of coil within and between sessions. Additionally, online access to navigation data is provided, hereby adding e.g. the ability to start or stop the magnetic stimulator depending on the distance to target or the variation of the orientation angles. Results StimTrack allows repeatable repositioning of the coil within 0.7 mm for translation and <1° for rotation. Stimulus-response (SR) curves obtained from 19 healthy volunteers were used to demonstrate that StimTrack can be effectively used in a typical experiment. An excellent intra and inter-session reliability (ICC > 0.9) was obtained on all parameters computed on SR curves acquired using StimTrack. Comparison with existing method StimTrack showed a target accuracy similar to that of a commercial neuronavigation system (BrainSight, Rogue Research Inc.). Indeed, small differences both in position (∼0.2 mm) and orientation (<1°) were found between the systems. These differences are negligible given the human error involved in landmarks registration. Conclusions StimTrack, available as supplementary material, is found to be a good alternative for commercial neuronavigation systems facilitating assessment changes in corticospinal excitability using TMS. StimTrack allows researchers to tailor its functionality to their specific needs, providing added value that benefits experimental procedures and improves data quality.
Original language | English |
---|---|
Pages (from-to) | 97-104 |
Journal | Journal of Neuroscience Methods |
Volume | 293 |
DOIs | |
Publication status | Published - 2018 |
Bibliographical note
Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-careOtherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.
Keywords
- Accuracy
- Coil positioning
- Intra and inter-session reliability
- Motor cortex
- Motor evoked potential
- Neuronavigation
- Repeatability
- Transcranial magnetic stimulation