TY - JOUR
T1 - Surface effects in simulations of scanning electron microscopy images
AU - Van Kessel, Luc
AU - Hagen, Cornelis W.
AU - Kruit, Pieter
PY - 2019
Y1 - 2019
N2 - Background: Monte Carlo simulations of scanning electron microscopy (SEM) images ignore most surface effects, such as surface plasmons. Previous experiments have shown that surface plasmons play an important role in the emission of secondary electrons (SEs).Aim: We investigate the influence of incorporating surface plasmons into simulations of low-voltage critical dimension SEM (CD-SEM).Approach: We use a modified inelastic scattering model, derived for infinite flat surfaces, and apply it to nonflat, but smooth, geometries. This simplification captures most qualitative effects, including both surface plasmons and a reduced interaction with bulk plasmons near interfaces.Results: We find that the SE signal hardly changes when surface interactions are turned on for a perpendicularly incident beam. When the incident beam is perfectly parallel to a surface, the SE signal does significantly increase. However, the beam must be extremely close to the surface for this effect to be appreciable. An SEM is unable to produce a beam that is both narrow and parallel enough to be noticeably affected.Conclusions: The position of edges may appear shifted under specific circumstances. In realistic situations, it is unlikely to be a large effect.
AB - Background: Monte Carlo simulations of scanning electron microscopy (SEM) images ignore most surface effects, such as surface plasmons. Previous experiments have shown that surface plasmons play an important role in the emission of secondary electrons (SEs).Aim: We investigate the influence of incorporating surface plasmons into simulations of low-voltage critical dimension SEM (CD-SEM).Approach: We use a modified inelastic scattering model, derived for infinite flat surfaces, and apply it to nonflat, but smooth, geometries. This simplification captures most qualitative effects, including both surface plasmons and a reduced interaction with bulk plasmons near interfaces.Results: We find that the SE signal hardly changes when surface interactions are turned on for a perpendicularly incident beam. When the incident beam is perfectly parallel to a surface, the SE signal does significantly increase. However, the beam must be extremely close to the surface for this effect to be appreciable. An SEM is unable to produce a beam that is both narrow and parallel enough to be noticeably affected.Conclusions: The position of edges may appear shifted under specific circumstances. In realistic situations, it is unlikely to be a large effect.
KW - Monte Carlo simulation
KW - scanning electron microscopy
KW - surface plasmons
UR - http://www.scopus.com/inward/record.url?scp=85074650934&partnerID=8YFLogxK
U2 - 10.1117/1.JMM.18.4.044002
DO - 10.1117/1.JMM.18.4.044002
M3 - Article
AN - SCOPUS:85074650934
SN - 1932-5150
VL - 18
JO - Journal of Micro/ Nanolithography, MEMS, and MOEMS
JF - Journal of Micro/ Nanolithography, MEMS, and MOEMS
IS - 4
M1 - 044002
ER -