Synthetic CT generation using Zero TE MR for head-and-neck radiotherapy

Iris Lauwers*, Marta Capala, Sandeep Kaushik, László Ruskó, Jean Paul Kleijnen, Jonathan Wyatt, Hazel McCallum, Gerda M. Verduijn, Juan Hernandez-Tamames, More Authors

*Corresponding author for this work

Research output: Contribution to journalArticleScientificpeer-review

34 Downloads (Pure)

Abstract

Background and Purpose: MRI-based synthetic CTs (synCTs) show promise to replace planning CT scans in various anatomical regions. However, the head-and-neck region remains challenging because of patient-specific air, bone and soft tissues interfaces and oropharynx cavities. Zero-Echo-Time (ZTE) MRI can be fast and silent, accurately discriminate bone and air, and could potentially lead to high dose calculation accuracy, but is relatively unexplored for the head-and-neck region. Here, we prospectively evaluated the dosimetric accuracy of a novel, fast ZTE sequence for synCT generation. Materials and Methods: The method was developed based on 127 patients and validated in an independent test (n = 17). synCTs were generated using a multi-task 2D U-net from ZTE MRIs (scanning time: 2:33 min (normal scan) or 56 s (accelerated scan)). Clinical treatment plans were recalculated on the synCT. The Hounsfield Units (HU) and dose-volume-histogram metrics were compared between the synCT and CT. Subsequently, synthetic treatment plans were generated to systematically assess dosimetry accuracy in different anatomical regions using dose-volume-histogram metrics. Results: The mean absolute error between the synCT and CT was 94 ± 11 HU inside the patient contour. For the clinical plans, 98.8% of PTV metrics deviated less than 2% between synCT and CT and all OAR metrics deviated less than 1 Gy. The synthetic plans showed larger dose differences depending on the location of the PTV. Conclusions: Excellent dose agreement was found based on clinical plans between the CT and a ZTE-MR-based synCT in the head-and-neck region. Synthetic plans are an important addition to clinical plans to evaluate the dosimetric accuracy of synCT scans.

Original languageEnglish
Article number110762
Number of pages7
JournalRadiotherapy and Oncology
Volume205
DOIs
Publication statusPublished - 2025

Keywords

  • Head and neck
  • MROnly
  • Synthetic CT
  • Zero TE MRI
  • ZTE

Fingerprint

Dive into the research topics of 'Synthetic CT generation using Zero TE MR for head-and-neck radiotherapy'. Together they form a unique fingerprint.

Cite this