TY - JOUR
T1 - Ventilation performance evaluation of an operating room with temperature-controlled airflow system in contaminant control
T2 - A numerical study
AU - Hu, Nan
AU - Lans, Jos
AU - Gram, Annika
AU - Luscuere, Peter
AU - Sadrizadeh, Sasan
PY - 2024
Y1 - 2024
N2 - This article investigates the efficacy of temperature-controlled airflow systems in modern operating rooms for contaminant control, a critical factor in preventing surgical site infections. We have conducted experimental measurements in an operating room equipped with temperature-controlled ventilation to map the airflow field and contaminant dispersion (airborne particles with diameters ranging from 0.5 to 1 μm). The results were used to validate the computational fluid dynamics code, which was then employed to simulate and examine different conditions, including contaminant release locations and air supply rates. Realizable k-epsilon and passive scalar models were utilized to simulate airflow and airborne particle phases. We assessed the airflow distribution and contaminant dispersion, utilizing indices such as ventilation and air change efficiency scales. The analysis provided quantitative insights into the distribution and removal of contaminants, as well as the speed at which the room air was replaced. Contamination was found to be effectively reduced when contaminants were released near exhaust outlets or under central unidirectional inlets. The presence of the operating table caused a big distortion of the central downward airflow, forming a horizontal air barrier at the periphery. Under this unique interior configuration, an appropriate air supply ratio between central and periphery zones was required to achieve optimal overall ventilation performance.
AB - This article investigates the efficacy of temperature-controlled airflow systems in modern operating rooms for contaminant control, a critical factor in preventing surgical site infections. We have conducted experimental measurements in an operating room equipped with temperature-controlled ventilation to map the airflow field and contaminant dispersion (airborne particles with diameters ranging from 0.5 to 1 μm). The results were used to validate the computational fluid dynamics code, which was then employed to simulate and examine different conditions, including contaminant release locations and air supply rates. Realizable k-epsilon and passive scalar models were utilized to simulate airflow and airborne particle phases. We assessed the airflow distribution and contaminant dispersion, utilizing indices such as ventilation and air change efficiency scales. The analysis provided quantitative insights into the distribution and removal of contaminants, as well as the speed at which the room air was replaced. Contamination was found to be effectively reduced when contaminants were released near exhaust outlets or under central unidirectional inlets. The presence of the operating table caused a big distortion of the central downward airflow, forming a horizontal air barrier at the periphery. Under this unique interior configuration, an appropriate air supply ratio between central and periphery zones was required to achieve optimal overall ventilation performance.
KW - Contaminant dispersion
KW - Numerical simulation
KW - Operating room
KW - Temperature-controlled ventilation
UR - http://www.scopus.com/inward/record.url?scp=85194167872&partnerID=8YFLogxK
U2 - 10.1016/j.buildenv.2024.111619
DO - 10.1016/j.buildenv.2024.111619
M3 - Article
AN - SCOPUS:85194167872
SN - 0360-1323
VL - 259
JO - Building and Environment
JF - Building and Environment
M1 - 111619
ER -