TY - JOUR
T1 - Flocculation of clay suspensions by anionic and cationic polyelectrolytes
T2 - A systematic analysis
AU - Shakeel, Ahmad
AU - Safar, Zeinab
AU - Ibanez, Maria
AU - van Paassen, Leon
AU - Chassagne, Claire
PY - 2020
Y1 - 2020
N2 - The characteristics of clayey suspensions, majorly composed of quartz microparticles, in the presence of anionic and cationic polyelectrolytes were investigated using different techniques. A wide range of clay concentrations was used, i.e., from 0.07 to 1000 g/L for different experimental techniques, based on the fact that the clay concentration possible to analyze with selected experimental methods was significantly different. The optimum flocculant to clay ratio was defined as the ratio that gives the fastest initial floc growth by static light scattering or fastest initial settling velocity by settling column experiments. In case of anionic polyelectrolyte, it was observed that the optimum flocculant dose depends on the amount of cations present in the system. For suspensions made with demi-water, a lower optimum flocculant dose (<1 mg/g) than for suspensions prepared in tap water (2.28 mg/g) was observed. At these lower salinities, the supernatant remained turbid in all the experiments and was, therefore, not a good measure for optimal anionic based flocculation. The equilibrium floc size at a given shear rate was found to be independent on the shear history of the floc and only dependent on the current applied shear. This was confirmed by both light scattering and rheological analysis. In case of cationic polyelectrolyte, the optimum flocculant ratio (5–6 mg/g) corresponded to the ratio that gives the lowest electrophoretic mobility for each clay concentration and to the ratio that gives the fastest settling velocity for the highest clay concentrations (12–15 g/L), where static light scattering measurements were not possible. All investigation techniques, therefore, proved to be good indicators for predicting the optimum flocculant to clay ratio. For the lowest concentrations (1.75–8.7 g/L) studied by settling column measurements, the optimum flocculant ratio was observed to increase with decreasing clay concentration, for fixed mixing conditions. The optimum flocculant to clay ratio was not always corresponding to the clearest supernatant and the size of flocs at optimum dosage was dependent on the mixing efficiency. The equilibrium floc size at a given shear rate was found to be dependent on the shear history of the floc and the current applied shear. This was confirmed by both light scattering and rheological analysis.
AB - The characteristics of clayey suspensions, majorly composed of quartz microparticles, in the presence of anionic and cationic polyelectrolytes were investigated using different techniques. A wide range of clay concentrations was used, i.e., from 0.07 to 1000 g/L for different experimental techniques, based on the fact that the clay concentration possible to analyze with selected experimental methods was significantly different. The optimum flocculant to clay ratio was defined as the ratio that gives the fastest initial floc growth by static light scattering or fastest initial settling velocity by settling column experiments. In case of anionic polyelectrolyte, it was observed that the optimum flocculant dose depends on the amount of cations present in the system. For suspensions made with demi-water, a lower optimum flocculant dose (<1 mg/g) than for suspensions prepared in tap water (2.28 mg/g) was observed. At these lower salinities, the supernatant remained turbid in all the experiments and was, therefore, not a good measure for optimal anionic based flocculation. The equilibrium floc size at a given shear rate was found to be independent on the shear history of the floc and only dependent on the current applied shear. This was confirmed by both light scattering and rheological analysis. In case of cationic polyelectrolyte, the optimum flocculant ratio (5–6 mg/g) corresponded to the ratio that gives the lowest electrophoretic mobility for each clay concentration and to the ratio that gives the fastest settling velocity for the highest clay concentrations (12–15 g/L), where static light scattering measurements were not possible. All investigation techniques, therefore, proved to be good indicators for predicting the optimum flocculant to clay ratio. For the lowest concentrations (1.75–8.7 g/L) studied by settling column measurements, the optimum flocculant ratio was observed to increase with decreasing clay concentration, for fixed mixing conditions. The optimum flocculant to clay ratio was not always corresponding to the clearest supernatant and the size of flocs at optimum dosage was dependent on the mixing efficiency. The equilibrium floc size at a given shear rate was found to be dependent on the shear history of the floc and the current applied shear. This was confirmed by both light scattering and rheological analysis.
KW - Anionic and cationic polyelectrolytes
KW - Clay
KW - Electrophoresis
KW - Particle size distribution
KW - Rheology
KW - Settling rate
UR - http://www.scopus.com/inward/record.url?scp=85095936531&partnerID=8YFLogxK
U2 - 10.3390/min10110999
DO - 10.3390/min10110999
M3 - Article
AN - SCOPUS:85095936531
SN - 2075-163X
VL - 10
SP - 1
EP - 24
JO - Minerals
JF - Minerals
IS - 11
M1 - 999
ER -