Ramp sinusoidal breakdown of epoxy resin under high voltage waveforms at different frequencies

Research output: Chapter in Book/Conference proceedings/Edited volumeConference contributionScientificpeer-review

25 Downloads (Pure)

Abstract

In this study, the immediate time to breakdown for pure epoxy resin is measured by applying a ramp sinusoidal voltage signal at certain frequency (50Hz, 500Hz and 5000Hz) until breakdown occurs. The HV testing procedures, epoxy resin sample and experimental set-up preparation and Weibull analysis of obtained results are elaborated. The experiments were carried out on epoxy samples with the thickness between 0.1mm and 0.2mm and the thickness was divided into three groups for more accurate statistical analysis.
Original languageEnglish
Title of host publication22nd International Symposium on High Voltage Engineering (ISH 2021)
Pages2083-2088
Number of pages6
Volume2021
Edition15
DOIs
Publication statusPublished - 2021

Bibliographical note

Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care
Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.

Fingerprint

Dive into the research topics of 'Ramp sinusoidal breakdown of epoxy resin under high voltage waveforms at different frequencies'. Together they form a unique fingerprint.

Cite this